SMARTDIVER   RAKE INTEGRATION

"THE RAKE INTEGRATION METHODOLOGY OF THE SMARTDIVER® UTILISES PROXIMITY TAGS & DIRECTIONAL PULSE SEQUENCING TO SYNCHRONISE ITS SENSOR DIVE CYCLES WITH RAKE ARM ROTATION."

Rake and Sensor0220.png

Projetado para o setor de processamento de minerais

On the Rake Drive, a Rake Switch is positioned at the SmartDiver®'s dive location, and a Rake Tag for the Rake Arm.

When the Rake Arm passes the dive position, the Tag triggers the Switch.

Using this signal to calculate when it is safe to dive.

SS 3.png
SS 1.png

Projetado para o setor de processamento de minerais

By using tags for both arms, the SmartDiver® receives a signal every 180°.

For bi-directional rake arms, each Tag will have two sections, for a small and a large pulse, spaced 3 to 5 inches apart.

In the forward direction, the large section's pulse comes first, then a gap, then the small section's pulse. Vice-versa for the reverse direction.